Network PA System for medium to massive projects



Intro


The XC-9000 system is a completely electronic network PA system based on the TCP/IP protocol. By leveraging the TCP/IP protocol, the system ensures the reliable and proper transmission of all information packets. Not just can it utilize existing local area network, such as LANs or the Internet, to transmit program signals, however also it can additionally be deployed on a dedicated broadcasting network.


The server is extremely powerful. Even when linked with a a great deal of terminals, it can simultaneously handle the exact same job smoothly. A single-server system can sustain up to 3000 terminals and enables server plunging. There are no constraints on the simultaneous program networks, accomplishing true full electronic broadcasting
.


System Qualities



Adaptable PA System Layout


The PA system style is basic, including service management software application, network microphones, network amplifiers, network speakers, and other devices.All devices is connected through the TCP/IP intranet protocol, permitting flexible configuration and simple management of the system, with complimentary control over broadcast web content, network devices, and areas via the network.


Ip Paging SystemSpon Communications
Comprehensive Audio Management


The audio management software application consists of built-in features for developing broadcast strategies, flexible zoning, and pre-scheduled broadcasts.It supports 24-hour shows, permitting transforming setups throughout throughout the day


Versatile Audio Resource Support


The system supports numerous types of audio resources for sending notices like online speech and BGM playback. Sound resources can come from digital music apps, CD/DVD gamers, microphones, and so on. On top of that, the system gives diverse functions of supporting various broadcasting attributes such as set up broadcasting, zoned broadcasting, and emergency broadcasting.


Fire Alarm System System Combination


The system has a fire alarm system function and can be incorporated into a fire alarm system. When the alarm main system obtains the worrying signals, the cable will certainly transmit the signal to tools, which causes the XC-9000, sending signals to audio speakers


Users might select to pre-programmed settings to activate full-area or zoned alarms in emergency situations. The alarm voices come in several forms and could be modified providing to demands. For example, individuals can change language setups, upload and modify their audio resources according to precise needs, such as intruding alarm systems, fire alarms or air help alarms, and so on





Fire Alarm System System Combination


The system has a fire alarm feature and can be incorporated into an emergency alarm system. When the alarm main device obtains the worrying signals, the cable television will transfer the signal to gadgets, which causes the XC-9000, sending signals to audio speakers


Customers might pick to pre-programmed setups to turn on full-area or zoned alarm systems in emergency situations. The alarm voices come in multiple forms and might be edited catering to needs. For instance, individuals can change language settings, upload and edit their audio sources according to specific demands, such as intruding alarms, fire alarm systems or air aid alarms, and so on





App Control for System Procedures


The system makes it possible for mobile app login and use, allowing customers to launch broadcasts and other operations to authorized terminals with the web server software application, making sure a practical and streamlined experience.


Integrated SIP Compatibility


The system not only enables SIP phones to log in, yet additionally can be connected to third-party SIP web server or IPPBX, which establishes a completely integrated and compatible communication system with seamless combination right into existing systems.


Open up SDK


When large project like smart park occurs, the system gives an open SDK incorporated right into third-party application systems - IP Speaker


System Framework



Key Features


Arranged Playback


The system has the ability to automatically broadcast according to the set up jobs as long as users submit the audio apply for each amount of time of the day to the server and produce a playback timetable.


Zone Broadcasting


The system can arbitrarily split a few network gadgets into different zones to play defined audio programs or send out statements to any marked location. The quantity of each gadget can be imp source from another location readjusted.


Real-time Broadcasting


The system can record and broadcast radio programs or other exterior audio sources in real-time, and at the same time relayed them in sync.


Fire Alarm System Assimilation


The system can be integrated with the smoke alarm system for control. When a fire alarm signal is caused, it immediately turns on the emergency program function and sustains adjacent floor alarms. It likewise permits manual emergency situation broadcasting by clicking a solitary switch.


SIP Phone Combination


The system can be integrated with SIP servers, enabling online speech of voice broadcasting using SIP phones to send statements anytime and anywhere.


CCTV Assimilation


The digital gadgets such as IP POE Audio speakers embraces the global standard ONVIF procedure, which enables their voices to be broadcast using VMS platforms. The terminals can likewise be incorporated with CCTV systems for integrated broadcast.


Main Products



Sound Monitoring Software XC-9000


B/S design, supports cross-platform applications.
Covers standard broadcasting system works, enabling dividing management.
Unified monitoring of terminals within the system, checking out work standing, and batch quantity adjustment, and so on.
Supports building multi-level server styles, releasing administration according to individual geographical areas.
Gives SDK advancement plans for secondary growth and integration with various other system platforms.


Network Paging Console XC-9038N


Power: DC12V/1.5 A.
Display: 4-inch touchscreen, resolution 480 * 480.
Interaction Protocols: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Frequency Feedback: 100Hz~ 16KHz.
Operating Temperature: 0~ 45 ℃.
Measurements: 144 * 144 * 34.1 mm.


Network Paging Console XC-9037N


Power Supply: DC12V/1.5 A.
Display: 4-inch touchscreen, resolution 480 * 480.
Communication Methods: TCP/IP, UDP, Visit This Link SIP.
Signal-to-Noise Proportion: > 80dB.
Frequency Feedback: 100Hz~ 16KHz.
Running Temperature: 0~ 45 ℃.
Measurements: 144 * 144 * 34.1 mm.


Network Horn Audio Speaker GEN-6391A03


Power Supply: DC24V/2.7 A or POE.
Communication Protocol: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Frequency Reaction: 100Hz~ 18KHz.
Intercom: Supported, Integrated Microphone.
Running Temperature: -20~ 50 ℃.
Measurements: 283.1 * 224.3 * 269mm.


Network Ceiling Speaker GEN-6211A03


Power Supply: DC 24V/1A or POE.
Communication Methods: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Frequency Response: 100Hz~ 18KHz.
Running Temperature: -20 to 50 ° C.
Dimensions: φ213 x 165mm.


Network Wall Surface Mount Audio Speaker GEN-6011A03


Power Supply: DC24V/1A or POE.
Interaction Procedure: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency Feedback: 100Hz~ 18KHz.
Running Temperature level: -20~ 50 ℃.
Measurements: 193x151.5 x292mm.


Network Column Audio Speaker GEN-6191A03




Power Supply: DC24V/1A or POE.
Communication Method: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 90dB.
Frequency Feedback: 45Hz~ 18KHz.
Running Temperature: -10~ 55 ℃.
Measurements: 296x140x130mm.


Network Audio Bridge GEN-3101A01


Power Supply: POE.
Interaction Protocol: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 85dB.
Frequency Response: 50Hz~ 20KHz.
Operating Temperature level: -10~ 55 ℃.
Measurements: 126x66x27mm.


Network Digital Amplifier XC-9508P


Power Supply: AC100V~ 240V, 50/60Hz.
Power: 130W, 260W, 360W, 500W.
Interaction Procedure: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Regularity Reaction: 60Hz~ 18KHz.
Operating Temperature level: -10~ 50 ℃.
Dimensions: 440x300x44mm.


Zone Combining Digital Amplifier NBS-2301


Power Supply : AIR CONDITIONER 220V, 50Hz.
Power : 130W , 260W , 360W , 550W , 700W.
Interaction Method : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP.
Signal-to-Noise Proportion :.
Mic Input 01: ≥ 65dB,.
Mic Input 02/03: ≥ 80dB,.
Aux Input 01/02: ≥ 82dB.
Regularity Response :.
Mic Input 01: 80Hz~ 14kHz.
Mic Input 02/03: 60Hz~ 16kHz.
Aux Input 01/02: 60Hz~ 16kHz.
Operating Temperature :.
10 ℃~ +50 ℃ (14 ℉~ 122 ℉)
Measurements : 483x430x88mm.


IP Interface Unit NAC-5003


Power Supply: AC100V~ 240V, 50/60Hz.
Interaction Protocol: TCP/IP, UDP.
Interfaces: 1 Ethernet port, 32 alarm system inputs, 8 alarm system outputs.
Running Temperature level: -10~ 50 ℃.
Measurements: 483x259x44mm.


Option For College





Flexible Zoning Program:


The totally network terminals can understand adaptable zoning alternatives, permitting transmitting alerts to different zones or private terminals ( tools).


Institution Bell System:


It supplies college bell system at the beginning/ending of the class - IP Paging Microphone. Several circumstances can be designed, consisting of different arranged program tasks according to summer/winter schedule


Emergency Alarm Integration


It supports combination with fire alarm system systems, permitting smoke alarm signals to be incorporated into the PA system.


Classroom Sound Amplification


Terminals sustain day-to-day applications in class scenes. They can be connected to projectors or interactive white boards for audio amplification.


Ip Pa SystemIp Pa System

Smart Road Lamp/Security Pole



Support SIP Procedure:


Integrated SIP method for smooth combination with network interaction systems.


VMS Platforms Combination:


Integrated ONVIF procedure for integration with VMS systems.


Third-Party Combination:


Constructed In HTTP API for integration with 3rd event platforms.


Voice Alarm System Activating:


Developed in alarm input interface for triggering voice alarm systems with video cameras.


Solution For Resort



Area Control by Floor:


The system uses full network settings, splitting areas counting on different floorings and control over each zone individually.


Emergency Alarm Integration:


The system can be integrated with emergency alarm system, allowing assimilation of emergency alarm signals right into the broadcasting system.


Scheduled Broadcasting:


It sustains programmable scheduled broadcasting, enabling flexible arrangements according to different needs.


Emergency Broadcasting:


It supports emergency situation broadcasting for the whole area, making it possible for one-click emergency situation interaction.


Option For Factory



Area Broadcasting:


It enables relaying to any kind of zone, guaranteeing no interference in between various locations.


Alarm Triggering:


Terminals have numerous sort of interfaces, allowing to trigger alarm systems when attached with video cameras.


All Network Tools:


Deployment of fully network tools considerably lowers the problem of running such as examining devices on hazardous sites, and therefore protecting individuals and home.


The implementation of all network tools significantly reduces the problem of procedure and maintenance monitoring


Integrated SIP Phones:


The system can be integrated with SIP phone and broadcast notices using SIP phones at any moment and anywhere. Two-way audio talkback in between SIP phones and IP POE Audio speakers makes it easy Recommended Reading for inspecting tools sitting in workplace or various other workplaces.


The XC-9000 system is a completely digital network PA system based on the TCP/IP method. By leveraging the TCP/IP protocol, the system ensures the right and efficient transmission of all information packets. The system sustains various types of audio resources for sending alerts like online speech and BGM playback. In enhancement, the system offers diverse functions of sustaining numerous broadcasting features such as arranged broadcasting, zoned broadcasting, and emergency broadcasting.


The system can be integrated with the fire alarm system for control.

Leave a Reply

Your email address will not be published. Required fields are marked *